Manufactured according to the recent USP, EP, JP and other pharmacopoeias. The DIST-3 is used for the manual testing of disintegration times of tablets, capsules and other solid dosage forms. The DIST-3 is a three-basket manual tablet disintegration testing instrument, Triple Basket Tablet Disintegration Tester 80 x 51 x 70cm (width x depth x height) PTZ AUTO 4 approx. 80 x 51 x 70cm (width x depth x height) PTZ AUTO 3 approx. 80 x 51 x 70cm (width x depth x height) PTZ AUTO 2 approx. 76 x 37 x 54cm (width x depth x height) PTZ AUTO 4 approx. 61 x 37 x 54cm (width x depth x height) PTZ AUTO 3 approx. 61 x 37 x 54cm (width x depth x height) PTZ AUTO 2 approx.

#Disintegration tester serial

RS-232 serial interface for external control and data transfer Water bath temperature programmable from 25.0° – 45.0☌, overheating protection 46 / 109kgĪll components certified to USP / EP requirements 80 x 51 x 70cm (width x depth x height) PTZ AUTO 4EZ approx. 80 x 51 x 70cm (width x depth x height) PTZ AUTO 3EZ approx. 80 x 51 x 70cm (width x depth x height) PTZ AUTO 2EZ approx. 76 x 37 x 54cm (width x depth x height) PTZ AUTO 4EZ approx. 61 x 37 x 54cm (width x depth x height) PTZ AUTO 3EZ approx. 61 x 37 x 54cm (width x depth x height) PTZ AUTO 2EZ approx. RS-232 serial interface for external control and data transfer Parallel PCL printer port (USB printer adapter available) Pressure switch to protect from overheating (no liquid flow – no heating – no pump) Thermo switch and thermo fuse to protect the heating system in case of electronical fault Programmable time sequence information to perform OQīuilt-in 1000 W heating tube and circulation pump, water bath temperature programmable from 25.0° – 45.0☌, overheating protection Password protection for calibration and validation

disintegration tester

Raises samples out of the medium at test end Programmable from 1 second up to 23h, 59m, 59s 90x120mmġ, 2, 3 or 4 stations – each independently operateable LED backlit LCD, 320×240 pixels, 9″ diagonal, approx. A result report including the individual disintegration times can be printed by connecting a PCL printer to the instrument. The total testing time for the station is displayed at the end of a run. Up to 16 different testing methods can be filed in the instrument’s memory. A test screen shows the run time information once a disintegration test is started. Operating ModeĪ large LCD screen and an alpha-numerical keyboard are used to edit product and test information, such as the target disintegration time for each station and the bath and media temperatures.

#Disintegration tester full

They are equipped in full compliance with the USP and EP pharmacopoeia requirements. Each automated disintegration basket can be operated independently and includes a temperature sensor.

disintegration tester

The instruments automatically detect the individual disintegration times of tablets and other solid dosage forms. The fully automated PTZ AUTO EZ instruments are available as single, double, triple and four station models. Fully Automated Tablet Disintegration Testing